doi:

DOI: 10.3724/SP.J.1096.2013.30229

Chinese Journal of Analytical Chemistry (分析化学) 2013/41:12 PP.1807-1811

A New Electrochemiluminescence Immunoassay Based on Magnetic Microbeads as Carrier of Labels


Abstract:
An ultrasensitive elctrochemiluminescense (ECL) immunoassay was proposed by using magnetic microbeads as the carrier of ECL labels for ECL signal amplification. First, polyclonal antibody (pcAb) of abrin was coated on microplate. Then, abrin was bound to pcAb. Next, biotinylated monoclonal antibody (mcAb) was conjugated to abrin, yielding the sandwich immunocomplex on the plate. After that, Ru(bpy)32+ labeled magnetic microbeads was conjugated on the plate through specific biotin-streptavidin interaction. Finally, Ru(bpy)32+ labeled magnetic microbeads was released from the plate and ECL of Ru(bpy)32+ was measured for abrin determination. A logarithmic linear relationship between ECL intensity and the concentration of abrin in the range of 2-200 μg/L was obtained, the linear regression equation was lgY=1.295lgX+0.201 (R=0.995, n=7,p<0.0001) and the detection limit was 2 μg/L. This new approach holds great promise for highly sensitive detection of target proteins in various fields such as biodiagnostics, environmental monitoring and biodefense.

Key words:Magnetic microbead,Electrochemiluminescence,Immunoassay,Abrin

ReleaseDate:2015-04-19 11:07:51



1 Pyati R, Richter M M. Annu. Rep. Prog. Chem. Sect. C: Phys. Chem., 2007, 103: 12-78

刘 冰, 童朝阳, 郝兰群, 刘 威, 穆晞惠, 黄启斌. 分析测试学报, 2013, 32(8): 998-1002

刘 冰, 童朝阳, 郝兰群, 穆晞惠, 刘 威, 黄启斌. 传感器与微系统, 2013, 32(5): 28-30

2 LIU Bing, TONG Zhao-Yang, HAO Lan-Qun, LIU Wei, MU Xi-Hui, HUANG Qi-Bin. Journal of Instrumental Analysis, 2013, 32(8): 998-1002

3 Yu H, Raymonda J W. Biosens. Bioelectron., 2000, 14(10-11): 829-840

穆晞惠, 童朝阳, 郝兰群, 许秀玲, 刘 冰, 田艳慧. 免疫学杂志, 2007, 23(5): 571-574

穆唏惠, 周志强, 童朝阳, 刘 冰, 郝兰群. 分析化学, 2009, 37(10): 1492-1502

4 Miao W, Bard A J. Anal. Chem., 2004, 76(23): 7109-7113

5 ZhuD B, Zhou X M, Xing D. Biosens. Bioelectron., 2010, (26): 285-288

6 LiM Y, Sun Y M, Chen L, Li L, Zou G Z, Zhang X L, Jin W R. Electroanalysis, 2010, 22(3): 333-337

7 Miao W, Bard A J. Anal. Chem., 2003, 75 (21): 5825-5834

8 Terpetschning E, Szmacinski H, Malak H, Lakowicz J R. J. Biophysical, 1995, 68: 342-350

9 LIU Bing, TONG Zhao-Yang, HAO Lan-Qun, MU Xi-Hui, LIU Wei, HUANG Qi-Bin. Transducer and Microsystem Technologies, 2013, 32(5): 28-30

10 MU Xi-Hui, TONG Zhao-Yang, HAO Lan-Qun, XU Xiu-Ling, LIU Bing, TIAN Yan-Hui. Immunological Journal, 2007, 23(5): 571-574

11 Garber E A, Walker J L, O'Brien T W. J. Food Prot., 2008, 71(9): 1868-1874

12 Zhou Y, Tian X L, Li Y S, Pan F G, Zhang Y Y, Zhang J H, Wang X R, Ren H L, Lu SY, Li Z H, Liu Z S, Chen Q J, Liu J Q. Food Chem., 2012, 135 (4): 2661-2665

13 Melchior W B, Tolleson W H. Anal. Biochem., 2010, 396(2): 204-211

14 MU Xi-Hui, ZHOU Zhi-Qiang, TONG Zhao-Yang, LIU Bing, HAO Lan-Qun. Chinese J. Anal. Chem., 2009, 37(10): 1492-1502

15 Gao S, Nie C, Wang J H, Wang J, Kang L, Zhou Y, Wang J L. J. Food Prot., 2012, 75 (1): 112-117

16 Yang W, Li X B, Liu G W, Zhang B B, Zhang Y, Kong T, Tang J J, Li D N, Wang Z. Biosens. Bioelectron., 2011,26 (8): 3710-3713