Abstract:
A method was developed to determine trace concentrations of phthalate ester (PAE) metabolites in human urine by using ultra high performance liquid chromatography-triple quadrupole mass spectrometry. Aliquots (2 mL) of human urine samples were purified using strong anion-exchange solid-phase extraction after enzymatic deconjugation by glucuronidase for 2 h. The separation was performed on a Waters ACQUITY UPLC BEH Phenyl column (100 mm×2.1 mm, 1.7 μ m) with gradient elution by 0.1% (v/v) acetic acid in acetonitrile and 0.1% (v/v) acetic acid aqueous solution. The concentrations of nine PAE metabolites were determined under a multiple reaction monitoring mode by negative electrospray ionization. Eight of the determined metabolites showed good linearities in the range of 0.39-200 μ g/L, and the ninth metabolite showed linearity in the range of 1.17-600 μ g/L with correlation coefficients > 0.995. The limits of detection ranged from 0.06 to 0.85 μ g/L, and the limits of quantification ranged from 0.20 to 2.80 μ g/L. The recovery rates at all three spiked levels ranged from 84.1% to 122% with relative standard deviations between 4.5% and 14.3%. The intra-and inter-day precisions were not more than 10.1% and 9.3%, respectively. The matrix effect and stability were found to be favorable for analysis. This method was utilized for the determination of 50 human urine samples. The detection rates of monocyclohexyl phthalate (MCHP) and monobenzyl phthalate (MBZP) were 0 and 44.0%, and the detection rates of the other seven PAE metabolites was 100%. This method has the advantage of convenient operation and good accuracy and stability, and is suitable for the quantitative determination of the nine PAE metabolites in human urine.

Key words:ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS),solid phase extraction (SPE),phthalate ester (PAE) metabolites,urine

ReleaseDate:2018-09-19 13:59:52



[1] Bernard L, Décaudin B, Lecoeur M, et al. Talanta, 2014, 129(21):39

[2] Diane K, Wang R, Richard P M, et al. Environ Res, 2011, 111(3):329

[3] Bo Y N, Li R, Zhang P J, et al. Chinese Journal of Chromatography, 2016, 34(9):868 薄艳娜, 李蓉, 张朋杰, 等. 色谱, 2016, 34(9):868

[4] Martinoandrade A J, Chahoud I. Mol Nutr Food Res, 2010, 54(1):148

[5] Mu X Y, Li C L, Huang Y, et al. China Environmental Science, 2017, 37(9):3566 穆希岩, 李成龙, 黄瑛, 等. 中国环境科学, 2017, 37(9):3566

[6] Nakane F, Kunieda M, Shimizu S, et al. J Toxicol Sci, 2012, 37(3):527

[7] Li M, Chen C, Guo Y. Environ Pollut, 2017, 229:655

[8] Joensen U N, Frederiksen H, Jensen M B, et al. Environ Heal Persp, 2012, 120(10):1397

[9] Chou Y, Huang C, Lee C C, et al. J Pediatr Endocrinol Metabm, 2009, 22:69

[10] GB 9685-2016

[11] Wang Y W, Chai M, Zeng N, et al. Environmental Chemistry, 2016, 35(2):364 王昱文, 柴淼, 曾甯, 等. 环境化学, 2016, 35(2):364

[12] Zhang L, Wang F, Ji Y, et al. Atmos Environ, 2014, 85(2):139

[13] Yan R, Shao M Y, Sun C H, et al. Chinese Journal of Analytical Chemistry, 2014, 42(6):897 闫蕊, 邵明媛, 孙长华, 等. 分析化学, 2014, 42(6):897

[14] Zhang Z M, Zhang H H, Li J L, et al. Chinese Journal of Analytical Chemistry, 2017, 45(3):348 张泽明, 张洪海, 李建龙, 等. 分析化学, 2017, 45(3):348

[15] Silva M J, Barr D B, Reidy J A, et al. Environ Health Persp, 2004, 112(3):331

[16] Saravanabhavan G, Guay M, Langlois É, et al. Int J Hyg Envir Heal, 2013, 216(6):652

[17] Silva M J, Samandar E, James L P J, et al. J Chromatogr B Analyt Technol Biomed Life Sci, 2007, 860(1):106

[18] Kato K, Silva M J, Larry L N, et al. Anal Chem, 2005, 77(9):2985

[19] Kang L, Liu H H, Liao S C, et al. Chinese Journal of Health Laboratory Technology, 2017, 27(23):3349 康莉, 刘红河, 廖仕成, 等. 中国卫生检验杂志, 2017, 27(23):3349

[20] Hu X J, Zhang M, Xu X Y, et al. Journal of Hygiene Research, 2012, 41(1):109 胡小键, 张淼, 徐肖雅, 等. 卫生研究, 2012, 41(1):109

[21] Guo Y, Alomirah H, Cho H S. Environ Sci Technol, 2011, 45(7):3138

[22] Zhu X N, Wang G Q, Zhou Z J, et al. Journal of Environmental and Occupational Medicine, 2015, 32(3):265 朱效宁, 汪国权, 周志俊, 等. 环境与职业医学, 2015, 32(3):265

[23] Feng Y L, Liao X, Grenier G, et al. Anal Methods, 2015, 7(19):8048

[24] Alves A, Covaci A, Voorspoels S. Chemosphere, 2017, 168:692

[25] Lin X T, Wang X Y, Xia D G, et al. Chinese Journal of Analytical Chemistry, 2011, 39(6):877 林兴桃, 王小逸, 夏定国, 等. 分析化学, 2011, 39(6):877

[26] Gao H, Xu Y Y, Sun L, et al. Chinese Journal of Chromatography, 2015, 33(6):622 高慧, 许媛媛, 孙丽, 等. 色谱, 2015, 33(6):622

[27] Li J, Qiao Q D, Zhuang J X, et al. Chinese Journal of Chromatography, 2016, 34(2):170 黎娟, 乔庆东, 庄景新, 等. 色谱, 2016, 34(2):170

[28] EPA 821-R-16-006

[29] Net S, Delmont A, Sempéré R, et al. Sci Total Environ, 2015(515/516):162