doi:

DOI: 10.3724/SP.J.1123.2018.09020

Chinese Journal of Chromatography (色谱) 2019/37:2 PP.143-148

Preparation and performance evaluation of a novel polar urea-propyl-C30 stationary phase


Abstract:
A novel polar urea-propyl-C30 (TPU-C30) reversed stationary phase was prepared by using 3-ureidopropyltrimethoxysilane as a coupling agent. The characteristics of TPU-C30 were analyzed by scanning electron microscopy, elemental analysis, infrared spectroscopy and thermal analysis. The results showed that the TPU-C30 stationary phase was successfully prepared. Furthermore, the relative deviations of the element contents of TPU-C30 were within 5% (n=3), which indicated that the proposed synthesis had good repeatability. The chromatographic performances in the stationary phase were evaluated by using different polar compounds, positional isomers and basic compounds as solute probes. Compared to the conventional C18 and C30 columns, the TPU-C30 stationary phase had different selectivity and better shape selection. The TPU-C30 stationary phase can be applied in various fields.

Key words:high performance liquid chromatography (HPLC),polar embedding,polar urea-propyl-C30 (TPU-C30) stationary phase,preparation,shape selection

ReleaseDate:2019-02-14 09:31:18



[1] Zhang W W. Reading and Writing:Educational Teaching Research, 2011(18):255 张卫卫. 读写算:教育教学研究, 2011(18):255

[2] Sha J, Li T, Ren B Z. Henan Chemical Industry, 2016, 33(8):15 沙娇, 李涛, 任保增. 河南化工, 2016, 33(8):15

[3] Chen L F. China Health Standards Management, 2016, 7(6):115 陈丽芳. 中国卫生标准管理, 2016, 7(6):115

[4] Zhang P P, Zhuang W, Chen Q, et al. Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2016, 52(4):373 张培培, 庄韦, 陈强, 等. 理化检验-化学分册, 2016, 52(4):373

[5] O'Gara J E, Walsh D P, Phoebe Jr C H, et al. LC GC N Am, 2001, 19(6):632

[6] Layne J. J Chromatogr A, 2002, 957(2):149

[7] Wang H, Chen L, Tang X L, et al. J Chromatogr A, 2013, 1271(1):153

[8] Janas P, Bocian S, Jandera P, et al. J Chromatogr A, 2016, 1429:198

[9] Liu X D, Bordunov A, Tracy M, et al. J Chromatogr A, 2006, 1119(1/2):120

[10] Carabias-Martínez R, Rodríguez-Gonzalo E, Smith N W, et al. Electrophoresis, 2010, 27(22):4423

[11] Chen J Y, Jiang R, Jia Y Y, et al. Chemical Reagents, 2015, 37(3):205 陈佳音, 姜茹, 贾艳艳, 等. 化学试剂, 2015, 37(3):205

[12] Mignot M, Jores C D S, Tchapla A, et al. J Chromatogr A, 2017, 1512:9

[13] Zhang X, Li H, Zhang L, et al. Anal Sci, 2018, 34(4):445

[14] Borgesmunoz A C, Colon L A. J Sep Sci, 2016, 39(17):3469

[15] Sauter E, Gilbert C O, Boismenulavoie J, et al. J Phys Chem C, 2017, 121(41):23017

[16] Vyňuchalová K, Jandera P. Chromatographia, 2015, 78(13/14):861

[17] Mingliang Z, Wenpeng M, Liang Z, et al. J Chromatogr A, 2015, 1388:133

[18] Liu H, Zhang M, Yong G, et al. Food Chem, 2016, 204:56