doi:

DOI: 10.3724/SP.J.1249.2017.03284

Journal of Shenzhen University Science and Engineering (深圳大学学报理工版) 2017/34:3 PP.284-289

A new filter function for the image reconstruction of cone beam X-ray CT


Abstract:
The conventional filter function of the FDK algorithm in X-ray computed tomography (CT) can result in the obvious Gibbs phenomenon, which has great effect on the CT image. A NEW-MS-L filter function is deduced based on the rationale of mixed filter theory and weighted average theory. First, the S-L filter function is weighted and averaged to form M3S-L filter function.Then, as a superposition of the M3S-L filter function and the NEW filter function, the NEW-MS-L filter function is obtained. Compared with the other filter functions such as NEW, R-L-S-L, R-L-NEW, and R-L-MS-L, the NEW-MS-L can suppress the Gibbs phenomenon while maintaining high resolution. The results show that the NEW-MS-L filter function can provide X-ray CT with better reconstruction images.

Key words:optical engineering,computed tomography,FDK algorithm,filter function,Gibbs phenomenon,mixed filter theorem,weighted average theorem

ReleaseDate:2017-06-16 14:08:44



[1] Egan C K,Jacques S D M,Wilson M D, et al.3D chemical imaging in the laboratory by hyperspectral X-ray computed tomography[J].Scientific Reports,2015,5: 15979.

[2] Bieberle M,Barthel F.Combined phase distribution and particle velocity measurement in spout fluidized beds by ultrafast X-ray computed tomography[J].Chemical Engineering Journal,2016,285:218-227.

[3] Edlund R,Skorpil M,Lapidus G,et al.Cone-beam CT in diagnosis of scaphoid fractures[J].Skeletal Radiology,2016,45(2):197-204.

[4] Senyshyn A,Mühlbauer M J,Dolotko O,et al.Homogeneity of lithium distribution in cylinder-type Li-ion batteries[J].Scientific Reports,2015,5:18380.

[5] Plessis A D, Olawuyi B J, Boshoff W P, et al. Simple and fast porosity analysis of concrete using X-ray computed tomography[J]. Materials and Structures, 2016, 49(1): 553-562.

[6] Feldkamp L A, Davis L C, Kress J W. Practical cone-beam algorithm[J]. Journal of the Optical Society of America A, 1984, 1(6): 612-619.

[7] Wei Yuchuan, Wang Ge, Hsieh J. An intuitive discussion on the ideal ramp filter in computed tomography (I)[J]. Computers & Mathematics with Applications, 2005, 49(5/6): 731-740.

[8] 谢 强.计算机断层成像技术:原理、设计、伪像和进展[M].张朝宗,郭志平,王宗贤,译.北京:科学出版社,2006. Hsieh J.Computed tomography: principle, design, artifacts and recent advances[M]. Zhang Chaozong,Guo Zhiping, Wang Zongxian, trans. Beijing: Science Press,2006.(in Chinese)

[9] 胡永梅,全 红,徐利明,等.新型混合滤波器在FDK算法中的应用[J].中国医学影像技术,2011,27(2):397-400. Hu Yongmei, Quan Hong, Xu Liming, et al. Application of a new mixed filter in FDK algorithm [J]. Chinese Journal of Medical Imaging Technology, 2011, 27(2): 397-400.(in Chinese)

[10] 王晓鹏,王明泉,侯慧玲.基于R-L-MS-L滤波函数的CT图像重建[J].电视技术,2014,38(7):26-28. Wang Xiaopeng,Wang Mingquan,Hou Huilin. CT image reconstruction based on R-L-MS-L filter function[J].Video Engineering, 2014,38(7): 26-28.(in Chinese)

[11] 闫 镔,李 磊.CT图像重建算法[M].北京:科学出版社,2014. Yan Bin,Li Lei.CT image reconstructinalgorithm[M].Beijing:Science Press,2014.(in Chinese)

[12] 郑君里.信号与系统[M].北京:高等教育出版社,2002. Zhen Junli. Signals and systems[M].Beijing:Higher Education Press,2002.(in Chinese)

[13] 杨位钦,顾 岚.时间序列分析与动态数据建模[M].北京:北京工业学院出版社,1986. Yang Weiqin,Gu Lan. Time series analysis and dynamic data modeling [M].Beijing:Beijing Institute of Tchnology Press,1986.(in Chinese)

[14] 范惠荣,徐茂林,邱 钧,等.关于CBP算法的一种新型滤波函数和它的性质[J].电子学报,2004,32(2):232-235. Fan Huirong,Xu Maolin,Qiu Jun,et al. A new filter function in CBP and its properties[J].Acta Electronica Sinica,2004,32(2):232-235.(in Chinese)

[15] 刘 晓,杨朝文.RL滤波函数的改进对卷积反投影图像重建的影响[J].四川大学学报自然科学版, 2004,41(1):112-117. Liu Xiao,Yang Chaowen. The influence of modified-RL filter function on the quality of image reconstruction using convolution backprojection algorithm [J].Journal of Sichuan University Natural Science Edition,2004,41(1):112-117.(in Chinese)

[16] 刘 泽,孙丰荣,李艳玲,等.基于3D Shepp-Logan头部模型的三维医学图像重建仿真[J].生物医学工程学杂志,2006,23(5):938-943. Liu Ze,Sun Fengrong,Li Yanling, et al.The three-dimension medical image reconstruction simulation on 3D Shepp-Logan head phantom [J].Journal of Biomedical Engineering,2006,23(5):938-943.(in Chinese)

[17] Lei Yaohu,Huang Jianheng,Liu Xin,et al.Improvement of visibility of moir fringe in X-ray differential phase-contrast imaging[J].Journal of Shenzhen University Science and Engineering,2016, 33(5):506-510.

[18] 刘 鑫,郭金川.部分相干光源微分相衬双图像相位恢复[J].深圳大学学报理工版,2014,31(2):169-173. Liu Xin,Guo Jinchuan.Dual-images phase retrieval in differential phase-contrast imaging with partial coherence source[J].Journal of Shenzhen University Science and Engineering,2014,31(2):169-173.(in Chinese)

[19] Jerjen I, Revol V, Kottler C, et al. Phase contrast cone beam tomography with an X-ray grating interferometer [C]//International Conference on Advanced Phase Measurement Methods in Optics & Imaging.Ascona, Switzerland: American Institute of Physics, 2010, 1236(1):227-231.

[20] Huang Zhifeng, Kang Kejun, Li Zheng, et al. Direct computed tomographic reconstruction for directional-derivative projections of computed tomography of diffraction enhanced imaging[J]. Applied Physics Letters, 2006, 89(4): 041124.

[21] McCann M T, Nilchian M, Stampanoni M, et al. Fast 3D reconstruction method for differential phase contrast X-ray CT[J]. Optics Express, 2016, 24(13): 14564-14581.

[22] Fu Jian, Hu Xinhua, Velroyen A, et al. 3D algebraic iterative reconstruction for cone-beam X-ray differential phase-contrast computed tomography[J]. PloS One, 2015, 10(3): e0117502.